Brine Tank Water Level Too High
In this video tom from discount water softeners describes how much water should be in your brine tank.
Brine tank water level too high. It is normal to have some water in the brine tank. In the even that too much water is added to the brine tank the safety float will shut off the water flow to the brine tank avoiding a flood. The water level or briny water or brine level in a water softener brine tank may be abnormally high or it may simply fail to drop when the water softener goes through a regeneration cycle. Brine tank water level is about 8 to 10 inches.
1 2 hour may not be enough. Water softeners and air filtration systems waterboss 900 brine tank high water level have had the wb 900 about 8 years. Has done well until recently. The brine line has become detached from the top of the float yes it does.
I was adding salt pellets to the brine storage tank and the water. On the systems we sell the first 1 2 hour is the fill part of the cycle. These are some of the potential causes we ll start with the most common first. If there is high level of water in the brine tank salt tank check the following.
This tube will often have a lid on it. Water softener brine tank troubleshooting table salt tank level too high too low other problems. Brine tank not draining. Here we list the common causes of these two conditions followed by a diagnostic table followed by step by step suggestions of parts to check on the water softener and its brine tank.
One of the most common symptoms of a poorly functioning water softener is when the water level in the brine tank is too high. On ours the fill is a half hour but the fill is also controled by the tank float so when the water reaches a pre set level it stops and the system does nothing for the rest of the time until the next part of the cycle. The safety float is a mechanical device that usually sits in a 4 diameter white tube that s inside the brine tank. Post a question or comment about how to diagnose water softener salt dosing tank or brine tank operating problems.
If it is set too high excess water may build up and your unit may not be able to release all the water after each discharge cycle. The safety float has two purposes. Remove the water level indicator entire component in the image above disassemble it and determine if the valve itself requires. Water softeners and air filtration systems water level in brine storage tank too high i have ge water softener model gnsf23z.
The water softener float valve controls the water levels in the brine tank.